Simulation settings

<< Click to Display Table of Contents >>

Navigation:  The graphical user interface > Main Window > ATP menu > ATP Settings Dialog >

Simulation settings

 

The following table describes the Simulation settings available in the ATP Settings dialog box:

 

 

Simulation type. Select between

Time domain

Frequency Scan

Harmonic Frequency Scan

 

If Frequency Scan is selected the FREQUENCY SCAN option of ATP is enabled.

min:        Starting frequency for the frequency scan

max:        Ending frequency for the frequency scan

df:        Frequency increment. Leave 0 in logarithmic scan

NPD:        Number of frequencies per decades in logarithmic scan.

 

If Frequency Scan or Harmonic is selected the user can select which component of the solution to print out.

Magnitude only: Default request

Magnitude & Angle: POLAR OUTPUT VARIABLES

Magnitude & Angle & Real/Imag: BOTH POLAR AND RECTANGULAR

Real/Imag: RECTANGULAR OUTPUT VARIABLES

Other combinations are illegal and are prevented by button logic.